Diesel Gensets - High Speed, Air-Cooled (BTA)
 - 3.5 kVA to 7.5 kVA [1 & 3 Phase]


TECHNICAL DATA ( STANDARD GENSETS)
Petter Type, High Speed, Air-Cooled (FTA & BTA) Diesel Gensets (Direct Coupled)
1-Phase, 240 Volts, 1500 RPM, 50 Hz, 4 Poles & 1.0 Unity Power Factor
Sr.
No.
Genset Model No.
Resistive Type
&
Inductive Type
A.C. Generator Data kVA (kW) (Max.-Amp)

Model No. R & I Type
Diesel Engine Data
HP (kW) (No. Of Cyl.)
&
Model No. F & B Type
Resistive Type
Genset Weight with M.S.Base Frame
Nett/Gross (kgs)
Inductive Type
Genset Weight with M.S.Base Frame
Nett/Gross (kgs)
1 76AS-RB
77AS-RB
3.5 (3.5) (14.6)
35KS-R
7.5 (5.5) (One)
76A-BTA, 77A-BTA
285 / 435 (76AS-RB)
290 / 440 (77AS-RB)
---
2 85AS1-RB
85AS1-IB
5.0 (5.0) (20.8)
50KS-R, 50KS-I
10.0 (7.35) (One)
85A-BTA
330 / 480
85AS1-RB
335 / 485
85AS1-IB
3 85AS-RB
85AS-IB
6.0 (6.0) (25.0)
60KS-R, 60KS-I
10.0 (7.35) (One)
85A-BTA
340 / 490
85AS-RB
345 / 495
85AS-IB
3-Phase, 415 Volts, 50 Hz, 4 Poles & 0.8 Power Factor (Lagging)
4 57AT-RB
67AT-RB
5.0 (4.0) (7.0)
50KT-R
8.0 (5.9) (One)
57A-BTA, 67A-BTA
325 / 475
57AT-RB, 67AT-RB
---
5 85AT1-RB
85AT1-IB
6.5 (5.2) (9.0)
65KT-R, 65KT-I
10.0 (7.35) (One)
85A-BTA
345 / 495
85AT1-RB
330 / 480
85AT1-IB
6 85AT-RB
85AT-IB
7.5 (6.0) (10.4)
75KT-R, 75KT-I
10.0 (7.35) (One)
85A-BTA
350 / 500
85AT-RB
335 / 485
85AT-IB
 

Note = All Above Diesel Engines Comprised With Gensets Are Having Governing Class A2.

  • FTA = Fan Type Air-Cooled
  • BTA = Blower Type Air-Cooled

(i) Resistive (Load) Type A.C.Generators Are Made of M.S. body & Are Double Ball Bearing Type. These Are Self Excited, Drip Prrof, Screen Protected & Self Ventilated. Class of Winding is 'F' & Are Diode Type. The Degree of Protection is IP21. Voltage regulation is +/- 10%
Resistive (Load) Type Diesel Gensets Are Suitable For Light Duty / Low Torque Load Applications Such As Lightening, Electric Fans & Other Light Duty Domestic Loads etc...

(ii) Inductive (Load) Type A.C.Generators Are Made of Aluminium body & Are Double Ball Bearing Type. These Are Self Excited, Drip Proof, Screen Protected & Self Ventilated. Class of Winding is 'H' & Are Transformer Type. The Degree of Protection is IP23. Voltage regulation is +/- 5% 
Brushless with AVR (Automatic Voltage Regulator) Type A.C. Generators Instead of Transformer Type A.C. Generators Can Also Be Made Available With Voltage Regulation +/- 1%.
Inductive (Load) Type Diesel Gensets Are Suitable For Heavy Duty / High Torque Load Applications Such As For Running Electric Motors, Submersible Pumpsets, Air-Conditioners etc...
For Any Type of Long Duration High Torque Load, Technically Different Specification & Site conditions, Diesel Genset Has To Be Selected Accordingly. For Such Application Kindly contact US for Right Selection.

(iii) These A.C.Generators Are Suitable For Running Under Ambient Temperature Less Than 40 Degree & Altitude Less Than 1000 Metres.

(iv) In Case, Resistive Or Inductive Type Genset Is Mounted On Rubber Wheel Trolley Instead Of M.S.Base Frame, The Additional Nett / Gross Weight Will Be As Under :
(a) For Genset With 1/2 cylinder Engine Mounted On 4 Rubber Wheel Trolley 15 kgs. Extra
(b) For Genset With 2 cylinder Engine Mounted On 6 Rubber Wheel Trolley 22.5 kgs. Extra